Search Our Site  
 
  Home FAQs Warranty About Us Contact Us Login

 
Product Catalog / Templates
 
 

Product Listing

The right product at the right price.

You can't afford to compromise your designs. Or your budget. And you won't, when you specify quality-made Monarch panic and exit devices. Monarch Devices are designed to meet or exceed all legal and regulatory requirements. They're sleek, functional, and durable. And they come in a wide variety of finishes and designs to match virtually any door requirement. Best of all, they're competitively priced to assure you of receiving the highest product value.

Our response is always the same. On time.

At Monarch, delivering the product on time is as important to us as it is to you. We've built our reputation on it. How do we respond so fast? We custom-make our products to order, using a combination of hands-on assembly and demand flow quality-control processes. So, you're assured of getting the quality products you need when you need them.

Monarch's 17 Series exit device is manufactured to handle tough, high-traffic situations. And its sleek design makes it an ideal application for the narrowest door stiles. Available in panic or fire exit construction, the 17 Series comes in stainless, brass, bronze and aluminum architectural, as well as MAL and M13 powder-coated finishes.
Functions (ANSI)

17-R
Rim, Type 1

17-V
Vertical
Rod, Type 2
17-C
Conc. Vert.
Rod, Type 8
BA or N (01) Exit only, no trim.
(F)-17-R-BA
(F)-17-V-BA
(F)-17-C-BA
DT or TDT (02) Entrance by trim when actuating bar is locked down. *
(F)-17-R-DT or TDT
(F)-17-V-DT or TDT
(F)-17-C-DT or TDT
C or P (03) Entrance by trim when actuating bar is locked down. *
(F)-17-R-P or C
(F)-17-V-P or C
(F)-17-C-P or C
PHB (04) Entrance by trim when latchbolt is retracted by key or set in a retracted position by key.      

T (05) Entrance by thumbpiece. Key locks or unlocks thumbpiece.

T(NL) (06) Key removable only when locked.

(F)-17-R-T


(F)-17-R-T(NL)

(F)-17-V-T


(F)-17-V-T(NL)

(F)-17-C-T


(F)-17-C-T(NL)

L or K (08) Entrance by knob or lever. Key locks or unlocks knob.


L(NL) or K(NL) (09)
Entrance by knob or lever only when released by key. Key removable only when locked.

(F)-17-R-L or K


(F)-17-L-K(NL) or L(NL)

(F)-17-V-L or K


(F)-17-V-L(NL) or K(NL)

(F)-17-C-L or K


(F)-17-C-L(NL) or K(NL)

SLP or SL (11) Entrance by control turnpiece. Key locks or unlocks control.


SLP(NL) or SL(NL) (12) Entrance by control turnpiece only when released by turning key. Key removable only when locked.

 

(F)-17-V-SL



(F)-17-V-SL(NL)

(F)-17-C-SLP or SL


(F)-17-C-SLP(NL) or
SL (NL)

* NOTE: Fire exit devices cannot be locked down. Some codes permit electric dogging and/or electric latch retraction with fail secure circuitry.

 

Also manufactured for demanding, high-traffic installations, the streamlined design of the 18 Series exit device eliminates crossbars and arms. All 18 Series devices are available in panic or A label (3 hr.) fire exit construction. Finishes include stainless, brass, bronze and aluminum architectural, as well as MAL and M13 powder-coated finishes.
Functions (ANSI)

18-R
Rim, Type 1

18-V
Vertical
Rod, Type 2
18-M
Mortise
Lock, Type 3
18-C
Conc. Vert.
Rod, Type 8
18-TPL**
Mortise & Vert. Rod, Type 11
BA or N (01) Exit only, no trim.
(F)-18-R-BA or N
(F)-18-V-BA or N
(F)-18-M-N
(F)-18-C-BA
(F)-18-TPL-BA or N
DT or TDT (02) Entrance by trim when actuating bar is locked down. *
(F)-18-R-DT
(F)-18-V-DT
(F)-18-M-DT
(F)-18-C-DT or TDT
(F)-18-TPL-DT
C or P (03) Entrance by trim when actuating bar is locked down. *
(F)-18-R-P or C
(F)-18-V-P or C
(F)-18-M-P or C
(F)-18-C-P or C
 
PHB (04) Entrance by trim when latchbolt is retracted by key or set in a retracted position by key.    
18-M-PHB
   

T (05) Entrance by thumbpiece. Key locks or unlocks thumbpiece.

T(NL) (06) Key removable only when locked.

(F)-18-R-T


(F)-18-R-T(NL)

(F)-18-V-T


(F)-18-V-T(NL)

(F)-18-M-T


(F)-18-M-T(NL)

(F)-18-C-T


(F)-18-C-T(NL)

 

T(2) (07) Entrance by thumbpiece. Inside key locks or unlocks thumbpiece. Outside key retracts latch.

T(2 O.C.) (07) Double outside cylinder.

(F)-18-R-T(2)



(F)-18-R-T
(2 O.C.)

(F)-18-V-T(2)




(F)-18-V-T
(2 O.C.)

(F)-18-M-T(2)

   

LE or KE (08) Entrance by knob or lever. Key locks or unlocks knob.

LE(NL) or KE(NL) (09) Entrance by knob or lever only when released by key. Key removable only when locked.

(F)-18-R-LE or KE


(F)-18-R-LE(NL) or KE(NL)

(F)-18-V-LE or KE


(F)-18-V-LE(NL) or KE(NL)

(F)-18-M-LE or KE


(F)-18-M-LE(NL) or KE(NL)

(F)-18-C-L or K


(F)-18-C-L(NL) or K(NL)

(F)-18-TPL-LE


(F)-18-TPL-LE(NL) or KE(NL)

LE(2) or KE(2) (10) Entrance by knob or lever. Inside key locks or unlocks knob. Outside key retracts latch.

LE(2 O.C.) or KE(2 O.C.) (10) One cylinder locks or unlocks knob. Other cylinder retracts latch.

(F)-18-R-LE(2) or KE(2)

(F)-18-R-LE (2 O.C.) or KE (2 O.C.)

(F)-18-V-LE(2) or KE(2)


(F)-18-V-LE (2 O.C.) or KE (2 O.C.)

(F)-18-M-LE(2) or KE(2)

   

SLP or SL (11) Entrance by control turnpiece. Key locks or unlocks control.

SLP(NL) or SL(NL) (12) Entrance by control turnpiece only when released by turning key. Key removable only when locked.

 

(F)-18-V-SL



(F)-18-V-SL(NL)

(F)-18-C-SL or SLP


(F)-18-C-SL(NL) or SLP(NL)

   
* NOTE: Fire exit devices cannot be locked down. Some codes permit electric dogging and/or electric latch retraction with fail secure circuitry.
** Not available in MAL or M13 finishes

 

A dependable workhorse, the 19 Series exit device is an economical answer to a variety of exit needs. It's available in panic or B label (1 1/2 hr.) fire exit construction. Where low cost and dependability are essential, the 19 Series is the right choice. Finishes include MAL powder-coated aluminum, M13 powder-coated dark bronze, and stainless steel. The 19 Series comes with a full complement of trim.
Functions (ANSI)

19-R
Rim, Type 1

19-V
Vertical
Rod, Type 2
BA or N (01) Exit only, no trim.
(F)-19-R-BA
(F)-19-V-BA
DT (02) Entrance by trim when actuating bar is locked down. *
(F)-19-R-DT
(F)-19-V-DT
C or P (03) Entrance by trim when actuating bar is locked down. *
(F)-19-R-P or C
(F)-19-V-P or C

T (05) Entrance by thumbpiece. Key locks or unlocks thumbpiece.

T(NL) (06) Key removable only when locked.

(F)-19-R-T


(F)-19-R-T(NL)

(F)-19-V-T


(F)-19-V-T(NL)

L or K (08) Entrance by knob or lever. Key locks or unlocks knob.

L(NL) or K(NL) (09) Entrance by knob or lever only when released by key. Key removable only when locked.

(F)-19-R-K or L


(F)-19-R-K(NL) or L(NL)

(F)-19-V-K or L


(F)-19-V-K(NL) or L(NL)

* NOTE: Fire exit devices cannot be locked down. Some codes permit electric dogging and/or electric latch retraction with fail secure circuitry.

 

The Monarch XX Series traditional design conveys durability. It can inexpensively meet the demands of high-traffic areas in either panic or A label (3 hr. ) fire exit construction. The XX Series is available in brass, bronze, stainless steel and aluminum architectural finishes.
Functions (ANSI)

XX-R
Rim, Type 1

XX-V
Vertical
Rod, Type 2
XX-M
Mortise
Lock, Type 3
XX-C
Conc. Vert.
Rod, Type 8
XX-TPL
Mortise & Vert. Rod, Type 11
BA or N (01) Exit only, no trim. (F)-XX-R-BA or N (F)-XX-V-BA or N (F)-XX-M-N (F)-XX-C-BA (F)-XX-TPL-BA
DT or TDT (02) Entrance by trim when actuating bar is locked down. * (F)-XX-R-DT (F)-XX-V-DT (F)-XX-M-DT (F)-XX-C-DT or TDT (F)-XX-TPL-DT
C or P (03) Entrance by trim when actuating bar is locked down. * (F)-XX-R-P or C   (F)-XX-M-P or C (F)-XX-C-P or C  
PHB (04) Entrance by trim when latchbolt is retracted by key or set in a retracted position by key.     XX-M-PHB    

T (05) Entrance by thumbpiece. Key locks or unlocks thumbpiece.

T(NL) (06) Key removable only when locked.

(F)-XX-R-T


(F)-XX-R-T(NL)

(F)-XX-V-T


(F)-XX-V-T(NL)

(F)-XX-M-T


(F)-XX-M-T(NL)

(F)-XX-C-T

(F)-XX-C-T(NL)

 

T(2) (07) Entrance by thumbpiece. Inside key locks or unlocks thumbpiece. Outside key retracts latch.

T(2 O.C.) (07) Double outside cylinder.

(F)-XX-R-T(2)




(F)-XX-R-T
(2 O.C.)

 

(F)-XX-M-T(2)

   

LE(2) or KE(2) (10) Entrance by knob or lever. Inside key locks or unlocks knob. Outside key retracts latch.

LE(2 O.C.) or KE(2 O.C.) (10) One cylinder locks or unlocks knob. Other cylinder retracts latch.

(F)-XX-R-LE(2) or KE(2)


(F)-XX-R-LE(2 O.C.) or KE(2 O.C.)

 

(F)-XX-M-KE(2) or (F)-XX-M-LE(2)

   

LE or KE (08) Entrance by knob or lever. Key locks or unlocks knob.

LE(NL) or KE(NL) (09) Entrance by knob or lever only when released by key. Key removable only when locked.

(F)-XX-R-LE or KE

(F)-XX-R-LE(NL) or KE(NL)

(F)-XX-V-LE or KE

(F)-XX-V-LE(NL) or KE(NL)

(F)-XX-M-LE or KE

(F)-XX-M-LE(NL) or KE(NL)

(F)-XX-C-L or K

(F)-XX-C-L(NL) or K(NL)

(F)-XX-TPL-LE

(F)-XX-TPL-LE(NL) or KE(NL)

SLP or SL (11) Entrance by control turnpiece. Key locks or unlocks control.

SLP(NL) or SL(NL) (12) Entrance by control turnpiece only when released by turning key. Key removable only when locked.

 

(F)-XX-V-SL


(F)-XX-V-SL(NL)

(F)-XX-C-SL or SLP


(F)-XX-C-SL(NL) or SLP(NL)

   
* NOTE: Fire exit devices cannot be locked down. Some codes permit electric dogging and/or electric latch retraction with fail secure circuitry.